• Newsroom
  • Contact
  • safe&easy
  • DE EN PL CZ
Results out of Read more Products View all results

Share

Share this page

You can share this page with others by sending the URL of the selected page.

Email LinkedIn
5150 Screw or rivet fastening from front or rear side en IM0007405
Screw or rivet fastening
from front or rear side
5150 Screw-on mounting from rear side  integrated thread  en IM0007406
Screw-on mounting from rear side
(integrated thread)
5150 Screw or rivet fastening from front or rear side en IM0007405
5150 Screw-on mounting from rear side  integrated thread  en IM0007406

Series: 5150

Phase_Out_Logo

Last order date: 15.12.2018

IEC Appliance Inlet C14 with High Frequency Filter, X2Y Technology, ECO design, Front- or Rear Side Mounting

8 Variants


Connectors (Inlets/Outlets)

C14
Connector Logo
70° C

Description 5150

Description

  • Panel mount: Screw-on version from front or rear side
  • 2 Functions: Appliance Inlet, High frequency line filter as standard, industrial and medical version, Protection class I
  • Quick connect terminals 6.3 x 0.8 mm

Unique Selling Proposition

  • Filter for highest frequencies
  • X2Y® Technology
  • Double shielding for best filter performance
  • Metal flange for optimal shielding

Characteristics

  • Very compact filter for frequencies up to 1 GHz
    Patented X2Y Technologie for broadband high frequency filtering
  • Double shielding for best filter performance
    One single filter design for the given current range
  • Designed for standard, industrial and medical applications
    Suitable for assembly in metal plated plastic housings
  • Suitable for use in equipment according to IEC 60950/60601
    Suitable for use in medical equipment according to IEC/UL 60601-1

Other versions on request

  • Solder terminals
  • Variant with notch for V-Lock mating Cordsets

Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset.

Date Podkategorie Language Title Download
21/02/2019
Flyers Angličtina (English) Flyer Components and Solutions for Medical Equipment
04/02/2019
White Paper Angličtina (English) White Paper Safety in medical Equipment
09/08/2018
Flyers Angličtina (English) Flyer V-Lock cord-retention safeguard
09/08/2018
White Paper Angličtina (English) White Paper Cord retention
13/07/2018
PCN Angličtina (English) All connectors PG06 PCN Change of configuration code PG06
15/06/2018
PCN Angličtina (English) 5150 PCN V-Lock
06/04/2018
White Paper Angličtina (English) White Paper Mating Connectors English
24/11/2017
White Paper Angličtina (English) White Paper Leakage currents
09/09/2017
White Paper Angličtina (English) White Paper Power Consumption
20/04/2016
PCS Angličtina (English) 5150 PCS
14/04/2015
PCN Angličtina (English) 5150 PCN Filter cases have a new surface

Ratings IEC

Ratings IEC


The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.

General information on electrical characteristics colors of fuses
Ratings IEC, UL/CSA

General information on the rated current and the rated voltage at EMC products
Rated Voltage
Rated current

The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.

Search approval information for different families

Approvals

10 A @ Ta 40 °C / 250 VAC; 50 Hz

Ratings UL/CSA

Ratings UL


The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.

General information on electrical characteristics colors of fuses
Ratings IEC, UL/CSA

General information on the rated current and the rated voltage at EMC products
Rated Voltage
Rated current

The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.

Search approval information for different families

Approvals

15 A @ Ta 40 °C / 250 VAC; 60 Hz

Leakage Current

Leakage Current


The leakage current is an electric current flowing in an undesirable current path. In EMC filters this is done by the applied Y-capacitors, which are used for noise suppression. Information on the amount and classification of leakage currents are explained in detail and are listed in the data sheets.
Leakage Current

standard < 0.5 mA (250 V / 60 Hz)
medical < 43/80 µA (250 V / 60 Hz)

Dielectric Strength

Dielectric Strength


Information abou the maximum permissible voltage, to avoid a voltage breakdown due to insulation damage.

Dielectric Strength

> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)

Allowable Operation Temperature

-25 °C to 85 °C

Climatic Category

Climatic Category


Disposition of components in categories for the assessment of mechanical and electrical properties.
Climatic Category

25/085/21 acc. to IEC 60068-1

IP-Protection

IP-Protection


The IP code consists of a two-digit number, which indicates the respective degree of protection.

The first digit specifies the protection from the penetration of foreign objects, the second digit the protection from water penetration with harmful effects.

Details about IP protection degree can be looked up in the general product information
IP-Protection

from front side IP40 acc. to IEC 60529

Protection Class

Protection Class


Class I: with ground; Class II: without ground

Detailed information relating to protection class can also be found in the general product information

Insulation cover

Suitable for appliances with protection class I acc. to IEC 61140

Terminal

Terminals


Terminals according IEC Standard.

Detailed information about terminals can be looked up in the date sheet or in the general product information.
Terminal

Quick connect terminals 6.3 x 0.8 mm

Panel Thickness S

Panel Thickness S



See details in drawing
Snapper

Screw: max 8 mm
Mounting screw torque max 0.5 Nm

Material: Housing

Themoplast / steel tin-plated, black / metallic, UL 94V-0

appliance inlet/-outlet

appliance inlet/-outlet


Connector type according to IEC 60320-1 resp. IEC 60320-2-2, UL498, CSA C22.2 no.42

Details on connectors and their names can be found in the general product information
Appliance Couplers
Mating Connectors
Term explanation
Special Connector Designs

C14 acc. to IEC 60320-1,
UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I

Line Filter

Filter Type


Filter classification according leakage current for easy reading:

Standard: < 0.5 mA
Medical: < 0.1 mA

Standard, medical and industrial version, IEC 60939, UL 1283, CSA C22.2 no. 8
Technical Details

MTBF

MTBF


The term MTBF is the English acronym Mean Time Between Failure and describes reliability of a component. The operating time of a system can be calculated based on thementioned value of the component. - The higher this value, the more reliable the component.
MTBF

> 3'300'000 h acc. to MIL-HB-217 F

Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals

SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.


Approvals

The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.


Approval Reference Type: 5150

Approval Logo Certificates Certification Body Description
Approval marks ENEC 10 VDE Certificate Number: 40023426
Approval marks cURus UL UL File Number: E72928


Product standards

Product standards that are referenced

Organization Design Standard Description
Partners IEC_Certification_Body Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes
Partners IEC_Certification_Body Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference
Partners IEC_Certification_Body Designed according to IEC 60127-6 Miniature fuses. Part 6. Fuse-holders for miniature fuse-links
Partners IEC_Certification_Body Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements
Partners UL_Certification_Body Designed according to UL 498 Standard for Attachment Plugs and Receptacles
Partners UL_Certification_Body Designed according to UL 1283 Electromagnetic interference filters
Partners CSA_Certification_Body Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Partners CSA_Certification_Body Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters


Application standards

Application standards where the product can be used

Organization Design Standard Description
Partners IEC_Certification_Body Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technology equipment.
Partners IEC_Certification_Body Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Approval marks CE Selbsteklaration SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008.
Environment_Safety RoHS_Logo_color_CMYK_tif SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/836
Environment_Safety China_RoHS_e_konform_eps SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS.
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.
 V_Lock_Logo SCHURTER AG V-Lock system are based on a matching plug-dose combination. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset.
Environment_Safety Medical.jpg SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1

Preview
 

Picture(s)

Type
 

Type Corresponds to a product series and includes various distinct variants. On the type of descriptive data are summarized, eg in the data sheet

Order Number
 

Order Number Unique part number for placing an order

Configuration key
 

Configuration key The configuration key of a product consists of the composite key values, which describe the different kinds of attribut distinction.

Comment
 

Comment CAD drawings are for modeling purposes only

Model Description
 

Model Description

IGS
 

IGS

Step
 

Step

Parasolid
 

Parasolid

DXF
 

DXF

5150
5150.0011.0
5150.1XXX.0 CAD-Model shows variation terminal 6.3x0.8 mm
5150
5150.0011.1
5150.0XXX.0 CAD-Model shows variation terminal 6.3x0.8 mm

Dimension [mm]

Front or rear side mounting for screws with nuts or blind rivets (panel cutout for frontside mounting)

Rear side mounting with pre-formed, threaded holes for M3 screws (panel cutout for rear side mounting)


Diagrams

Standard and industrial version

1) Line
2) Load
Medical M80 and standard version with bleed resistor

1) Line
2) Load

Technical Data of Filter-Components

Rated Current [A] Filter-Type Capacitance CX [nF] Capacitance CY [nF] R [MΩ]
10 Standard Version 1.25 2.5 -
10 Standard Version with Bleed Resistor 1.25 2.5 1
10 Industrial Version 2.35 4.7 -
10 Medical Version (M80) 0.225 0.45 1

Attenuation Loss

CISPR 17 Test Method

same attenuation loss with bleed resistor

Alternate Test Method

CISPR 17 Test Method

Alternate Test Method

CISPR 17 Test Method

Alternate Test Method

Comment about alternate test method see table of variants


Short Table of Variants 5150 Open complete table 5150


Rated Current IEC [A] Rated Current UL [A] Filter-Type Order Number

Variant Details


The link on the respective order number refers to a separat tab with specific detailed information .

This assures better readable information of the selected product.
Change to the tab All Products in order to show details of another variant.

This approach offers to use generic alias link to the product details:

www.schurter.xx/art/ [Order Number]

where the following variables are used:
- xx is the country specific domain
- [Order Number]

A=Most Popular

A=Most Popular


Most popular products have the following customer benefits:

- previously ordered by multiple customers
- generally in stock for immediate delivery
- early adoption or mature life cycle

Contact us for availability on other product variants, lead-times vary:
Contact-Form

Availability for all products can be searched real-time. Enter part number and required quantity:
Stock Check SCHURTER

Free Sample

Free Sample


Please ask for free sample in order to check if the products meets your requirement for your application. Send your delivery adress and your specific requirements.

Distributor Stock Check

Distributor Stock Check


The following links reffers to the inquiry form for distributors stock information of the selected products. It allows checking for the available amount and optionally to place an order at your selected partner.

The
Distributor Stock Check
Stock Check Distributor

...
 
10 15 Standard Version 5150.0011.0 - ...
10 15 Standard Version 5150.0011.1 - ...
10 15 Standard Version with Bleed Resistor 5150.0021.0 - ...
10 15 Standard Version with Bleed Resistor 5150.0021.1 - ...
10 15 Industrial Version 5150.0041.0 - ...
10 15 Industrial Version 5150.0041.1 - ...
10 15 Medical Version (M80) 5150.0031.0 - ...
10 15 Medical Version (M80) 5150.0031.1 - ...

The Alternate Test Method allows the measurement in the GHz frequency range whereas the CISPR 17 method does not cover frequencies above 30MHz. The insertion loss is measured in a throughput method (common mode) and a cross coupled method (differential mode). The differential mode measurement of the alternate test method is not directly comparable to the conventional measurement acc. CISPR 17.

Further information on the X2Y filter technology and on the alternate insertion loss measurement method can be found under www.schurter.com/info_emc

Mating Outlets/Connectors (13)

[Swipe to the left and right for more options]

4787

4787, Mounting: Screw-on mounting, Appliance Outlet: IEC Solder terminals, 10 A, Suitable for appliances with protection class I

4788

4788, Mounting: Snap-in version, Appliance Outlet: IEC Solder terminals or quick connect terminals, 10 A, Suitable for appliances with protection class I

5091

IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal

4022

4022 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13

4782

4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

4012

4012 Mounting: Power Supply Cord, 3 x 1 mm², Screw clamps, Connector: IEC C13

4785

4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

4300-06

4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

4781

4781 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C15

8101

8101 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C15

4784

4784 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C15

4771

4771 Mounting: Power Supply Cord, 3 x 1 mm² / 3 x 14 AWG, Screw clamps, Connector: IEC C15A

4772

4772 Mounting: 3 x 1 mm² / 3 x 14 AWG, Screw clamps, Connector: IEC C15A

Mating Outlets/Connectors shuttered (1)

[Swipe to the left and right for more options]

VAC13KS

VAC13KS, Overview, V-Lock cord retaining, diverse Connector IEC C13, diverse, black

Accessories (2)

[Swipe to the left and right for more options]

Assorted Covers

Rear Cover

Cord retaining kits

Cord retaining strain relief


cz.schurter.com
cz
cz
cze-CZ